1.使用范围
适用于飞速S5860-20SQ交换机
2.准备阶段
查看两台设备版本是否一致
查看设备版本信息
S5860-20SQ#show version
Fiberstore co.,Limited Internetwork operating system software series software, version 2.7.0F Bu'Id 91325
RELEASE SOFTWARE S5860-20SQ copyright()2021 by Fs.CoM Al Rights Reservedcompiled:2023-2-11
18:27:39 by sys.Image text-base:0x80010000 ROM:system Bootstrap
version 0.1.3,hardware version:Aserial num:cG2108180482N00998
ID num:20067014936system image file is "switch. bin'FS S5860-20SQ RISC262144K bytes of memory
16384k bytes of flashBase ethernet MAc Address:64:9d:99:28:88:c9
version:Bsnmp info:product ID:446system ID:1.3.6.1.4.1.13142.1.543.ovend ID:52642 S5860-20SQ
uptime is 0:00:08:48,The current time: 2000-1-1 0:8:59 Reboot history information:7:systemis rebooted by
No.power-on System is rebooted bicommand at 2008-3-21 3:17:23,uptime 0:00:11:02 NO.
S5860-20SQ#
3.堆叠配置
S5860-20SQ-1配置
S5860-20SQ-1_config#switch virtual domain 100
S5860-20SQ-1_config#switch 1
S5860-20SQ-1_config#switch 1 priority 200
S5860-20SQ-1_config#switch 1 description master
S5860-20SQ-1_config#port-member interface ForityGigabitEthernet 0/0/25
S5860-20SQ-1_config#port-member interface ForityGigabitEthernet 0/0/26
S5860-20SQ-1_config#switch crc errors 10 times 20
S5860-20SQ-1_config#switch convert mode virtual
S5860-20SQ-1#write
Saving current configuration...
OK!
S5860-20SQ-2配置
S5860-20SQ-2_config#switch virtual domain 100
S5860-20SQ-2_config#switch 2
S5860-20SQ-2_config#switch 2 priority 100
S5860-20SQ-2_config#switch 2 description slave
S5860-20SQ-2_config#port-member interface ForityGigabitEthernet 0/0/25
S5860-20SQ-2_config#port-member interface ForityGigabitEthernet 0/0/26
S5860-20SQ-2_config#switch crc errors 10 times 20
S5860-20SQ-2_config#switch convert mode virtual
S5860-20SQ-2#write
Saving current configuration...
OK!
4.线路连接

5.配置完成后检查
堆叠状态检查
S5860-20SQ#show switch virtual
Switch_id Domain_id Priority Position Status Role Description
1(1) 100(100) 200(200) LOCAL OK ACTIVE master
2(2) 100(100) 100(100) REMOTE OK STANDBY salve
S5860-20SQ#show switch virtual link port
SWITCH1 :
port AP STATE Peer-Port RX TX UPTIME
ForityGigabitEthernet 1/0/25 1 OK ForityGigabitEthernet 2/0/25 2711518 2590140 1d,0h,29m
ForityGigabitEthernet 1/0/26 1 OK ForityGigabitEthernet 2/0/26 160142 160188 1d,0h,29m
SWITCH2 :
port AP STATE Peer-Port RX TX UPTIME
ForityGigabitEthernet 2/0/25 1 OK ForityGigabitEthernet 1/0/25 2590151 2711538 1d,0h,29m
ForityGigabitEthernet 2/0/26 1 OK ForityGigabitEthernet 1/0/26 160188 160142 1d,0h,29m