查看设备版本信息
S3900-24T4S-R#show version
Fiberstore co.,Limited Internetwork operating system softwareseries software, version 2.2.0F Bu'Id 97914
RELEASE SOFTWARES3900-24T4S-R copyright()2021 by Fs.CoM Al Rights Reservedcompiled:2022-5-17
18:27:39 by sYs.Image text-base:0x80010000RoM:system Bootstrap
version 0.1.3,hardware version:Aserial num:cG2108180297N00336
ID num:20057004926system image file is "switch. bin'FS S3900-24T4S-R RISC262144K bytes of memory
16384k bytes of flashBase ethernet MAc Address:64:9d:99:28:88:c9PCB
version:Bsnmp info:product ID:446system ID:1.3.6.1.4.1.52642.1.446.0vend ID:52642S3900-24T4S-R-2
uptime is 0:00:08:48,The current time: 2000-1-1 0:8:59Reboot historyinformation:7:systemis rebooted by
No.power-onSystem is rebooted bicommand at 2000-1-1 0:11:13,uptime 0:00:11:02NO.
S3900-24T4S-R#
S3900-24T4S-R-1配置
S3900-24T4S-R-1_config#bvss
S3900-24T4S-R-1_config_bvss#bvss enable
Please write bvss configuration and reboot switch, if not bvss function invalid.
S3900-24T4S-R-1_config_bvss#bvss domain-id 1
S3900-24T4S-R-1_config_bvss#bvss member-id 1
S3900-24T4S-R-1_config_bvss#bvss mode normal
S3900-24T4S-R-1_config_bvss#bvss priority 254
S3900-24T4S-R-1_config_bvss#bvss interface 1 slot 0 port 27 group 1
S3900-24T4S-R-1_config_bvss#bvss interface 2 slot 0 port 28 group 1
S3900-24T4S-R-1_config_bvss#exit
Jan 1 00:33:18 %SYS-6-CONFIG: Configured from console 0 by admin
S3900-24T4S-R-1#write bvss-config
Saving current bvss configuration...
OK!
S3900-24T4S-R-2配置
S3900-24T4S-R-2_config#bvss
S3900-24T4S-R-2_config_bvss#bvss enable
Please write bvss configuration and reboot switch, if not bvss function invalid.
S3900-24T4S-R-2_config_bvss#bvss domain-id 1
S3900-24T4S-R-2_config_bvss#bvss member-id 2
S3900-24T4S-R-2_config_bvss#bvss priority 250
S3900-24T4S-R-2_config_bvss#bvss mode normal
S3900-24T4S-R-2_config_bvss#bvss interface 1 slot 0 port 27 group 2
S3900-24T4S-R-2_config_bvss#bvss interface 2 slot 0 port 28 group 2
S3900-24T4S-R-2_config_bvss#exit
Jan 1 00:15:35 %SYS-6-CONFIG: Configured from console 0 by admin
S3900-24T4S-R-2#write bvss-config
Saving current bvss configuration...
OK!
堆叠状态检查
S3900-24T4S-R#show bvss managementovss
member l management information:
active member:1,standby member:2
1group:1-2,rgroup:
orphan group:-1,normal group:-1
HT[1]:, HT[r]: ,HT[La]:
internal topology:0 ,global topol0gy:LINE-TOPO
L to member1:unknown R to member l:unknown2.
L to member1 R to member 2:unknown
L to member3 :unknown R to member 3:unknown
L to member4:unknown R to member 4:unknown
hg route
to member1:local
to member2:l
to member3:unreachable
to member4:unreachable